{"product_id":"chison-q8","title":"Chison Q8","description":"\u003ch2\u003eChison Q8 Compact Innovative Powerful\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cp\u003eChison Q8 is portable color Doppler ultrasound equipment which is available at KeeboMed Inc. at affordable rates. It supports up to 256 probes and has some of the most cutting-edge technologies with features like real-time, TDI, IMT, TEE scanning and more. This classic and innovative system ensures stunning image quality without compromising the frame rate.\u003c\/p\u003e\n\u003cp\u003eWith its cutting-edge technologies, Q8 is one of few pioneers in the world ,which incorporate sophisticated features like real-time TDI, IMT,TEE scanning into one completely portable box. A Work-flow oriented User Interface is built to allow user-friendly operation with minimum soft key entry. Ergonomical design of keyboard, double probe connectors, USB and DICOM connectivity makes your scanning FAST and EASY,and allow you focus more on your patients.\u003c\/p\u003e\n\u003cp\u003eFeatures:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImaging Modes: B, 2B, 4B, B\/M, B\/BC, CFM\u003c\/li\u003e\n\u003cli\u003ePW, HRPF, CW, PD, Directional PD\u003c\/li\u003e\n\u003cli\u003eFree hand 3D, Real-time 4D\u003c\/li\u003e\n\u003cli\u003e15” LCD monitor with 2 probe connectors\u003c\/li\u003e\n\u003cli\u003e320 GB hard disk and 2 USB ports\u003c\/li\u003e\n\u003cli\u003eTHI, Speckle Reduction, MCI and i-Image\u003c\/li\u003e\n\u003cli\u003eOptions: Biopsy kit, Extended Cardiac Package, Video Printer, PC Printer, DICOM 3.0 and trolley\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe all-digital Chison Q8 is one of a few pioneers in the world with such sophisticated technologies, features and benefits. Buy used portable Chison Q8 from KeeboMed Inc. and make accurate and fast diagnosis in specialties like abdomen, obstetrics, gynecology, cardiac, vascular, urology and MSK.\u003c\/p\u003e\n\u003ch2\u003eChison Q8 Ultrasound Full Specification\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e15-inch LCD color display\u003c\/li\u003e\n\u003cli\u003e4D upgradebale\u003c\/li\u003e\n\u003cli\u003e2 probe connectors\u003c\/li\u003e\n\u003cli\u003eErgonomic design of keyboard\u003c\/li\u003e\n\u003cli\u003eCompact, slim design made for easy portability\u003c\/li\u003e\n\u003cli\u003eUSB and DICOM connectivity\u003c\/li\u003e\n\u003cli\u003eTDI quantitative cardiac analysis\u003c\/li\u003e\n\u003cli\u003eReal-time 4D, TDI, TEE scanning\u003c\/li\u003e\n\u003cli\u003eSupports probes up to 256 elements\u003c\/li\u003e\n\u003cli\u003eDouble-phasing digital beam forming\u003c\/li\u003e\n\u003cli\u003eSpeckle Reduction Algorithm (SRA); supresses speckle while keeping true tissue architecture and better contrast.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Configuration\u003c\/strong\u003e\u003cbr\u003eMain Unit, 3.5 MHz Convex probe, 7.5 MHz Linear Probe, 15” LCD, 2 Probe con\u003cbr\u003enectors, Hard Disk (160GB), 2 USB ports\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImaging Modes\u003c\/strong\u003e\u003cbr\u003eB, 2B, 4B, B\/M\u003cbr\u003eB\/BC, CFM, Color M\u003cbr\u003ePW, HPRF, CW\u003cbr\u003ePD, Directional PD\u003cbr\u003eTDI (Tissue Doppler Color, Tissue Doppler PW)\u003cbr\u003eInstant Triplex, Duplex\u003cbr\u003eTrapezoidal, Panoramic\u003cbr\u003eFree Hand, 3D, Real-Time 4D\u003cbr\u003eChroma B\/M\/PW\/CW\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImage Processing Technology\u003c\/strong\u003e\u003cbr\u003eDouble Phasing Digital Beam Forming\u003cbr\u003eTHI on all probes\u003cbr\u003eSpeckle Reduction Algorithm (SRA)\u003cbr\u003eMultiple Compound Imaging (MCI)\u003cbr\u003ei-Image\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e\u003cbr\u003e6.0 MHz Transvaginal Probe\u003cbr\u003e3.0 MHz Phased Array Probe\u003cbr\u003e5.0 MHz Pediatric Probe\u003cbr\u003e5.0 MHz TEE probe (Adults)\u003cbr\u003eFree-hand 3D\u003cbr\u003eReal-Time 4D package: 4D software and 4D Volume Probe\u003cbr\u003eVideo Printer, PC printer\u003cbr\u003ei-Image\u003cbr\u003eDICOM\u003cbr\u003eTrolley\u003c\/p\u003e\n\u003ch3\u003eTISSUE DOPPLER IMAGING (TDI)\u003c\/h3\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www2.chison.com:8880\/images\/upfile\/image\/2012_11\/Q8-0530-1.jpg\" alt=\"\" width=\"680\" height=\"230\"\u003e\u003c\/p\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003ch3\u003eSPECKLE REDUCTION ALGORITHM (SRA)\u003c\/h3\u003e\n\u003cdiv\u003e\u003cimg src=\"http:\/\/www2.chison.com:8880\/images\/upfile\/image\/2012_11\/Q8-0530-2.jpg\" alt=\"\" width=\"680\" height=\"230\"\u003e\u003c\/div\u003e\n\u003ch3\u003eWORK-FLOW SOLUTION\u003c\/h3\u003e\n\u003cdiv\u003e\u003cimg src=\"http:\/\/www2.chison.com:8880\/images\/upfile\/image\/2012_11\/Q8-0530-3.jpg\" alt=\"\" width=\"680\" height=\"400\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3\u003eTRANSDUCERS\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca title=\"D7C10L\" href=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/2012117161618677.jpg\" rel=\"fancybox\"\u003e\u003cimg src=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/2012117161612479.jpg\" alt=\"\"\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003ch4\u003eD7C10L\u003c\/h4\u003e\n\u003cp\u003e7.5MHz Transvaginal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"D5C20L\" href=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/201356143648400.jpg\" rel=\"fancybox\"\u003e\u003cimg src=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/201356143639134.jpg\" alt=\"\"\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003ch4\u003eD5C20L\u003c\/h4\u003e\n\u003cp\u003e5.0MHz Pediatric\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"V4C40L\" href=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/20135614365624.jpg\" rel=\"fancybox\"\u003e\u003cimg src=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/20135614364384.jpg\" alt=\"\"\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003ch4\u003eV4C40L\u003c\/h4\u003e\n\u003cp\u003e4.0MHz 4D Volume\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"D7L40L\" href=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/201356143326640.jpg\" rel=\"fancybox\"\u003e\u003cimg src=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/201356143321371.jpg\" alt=\"\"\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003ch4\u003eD7L40L\u003c\/h4\u003e\n\u003cp\u003e7.5MHz Linear\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"D6P64L\" href=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/201356134628553.jpg\" rel=\"fancybox\"\u003e\u003cimg src=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/201356134623725.jpg\" alt=\"\"\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003ch4\u003eD6P64L\u003c\/h4\u003e\n\u003cp\u003e6.0MHz Phased array\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"D6C15L\" href=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/201211149440428.jpg\" rel=\"fancybox\"\u003e\u003cimg src=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/201211149432693.jpg\" alt=\"\"\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003ch4\u003eD6C15L\u003c\/h4\u003e\n\u003cp\u003e6.0MHz Pediatric\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"D6C12L\" href=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/201211149233755.jpg\" rel=\"fancybox\"\u003e\u003cimg src=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/201211149227630.jpg\" alt=\"\"\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003ch4\u003eD6C12L\u003c\/h4\u003e\n\u003cp\u003e6.0MHz Transvaginal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"D3P64L\" href=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/201211149013995.jpg\" rel=\"fancybox\"\u003e\u003cimg src=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/20121114904465.jpg\" alt=\"\"\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003ch4\u003eD3P64L\u003c\/h4\u003e\n\u003cp\u003e3.0MHz Phased array\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"D3C60L\" href=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/201356134544316.jpg\" rel=\"fancybox\"\u003e\u003cimg src=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/201356134538531.jpg\" alt=\"\"\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003ch4\u003eD3C60L\u003c\/h4\u003e\n\u003cp\u003e3.5MHz Convex\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCLINIC VALUE AND APPLICATIONS\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"Kindey, PD Mode\" href=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/201211716251131.jpg\" rel=\"fancybox_a\"\u003e\u003cimg src=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/2012117162458504.jpg\" alt=\"\"\u003eKindey, PD Mode\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca title=\"Pancreas,B Mode\" href=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/2012117162513988.jpg\" rel=\"fancybox_a\"\u003e\u003cimg src=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/201211716259549.jpg\" alt=\"\"\u003ePancreas,B Mode\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca title=\"Liver,B\/BC Mode\" href=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/2012117162524277.jpg\" rel=\"fancybox_a\"\u003e\u003cimg src=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/2012117162521179.jpg\" alt=\"\"\u003eLiver,B\/BC Mode\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca title=\"Aorta , DMode\" href=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/2012117162536319.jpg\" rel=\"fancybox_a\"\u003e\u003cimg src=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/2012117162534492.jpg\" alt=\"\"\u003eAorta , DMode\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca title=\"Liver,Direct PD Mode\" href=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/2012117162557752.jpg\" rel=\"fancybox_a\"\u003e\u003cimg src=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/2012117162553987.jpg\" alt=\"\"\u003eLiver,Direct PD Mode\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca title=\"Kindey, CFM Mode\" href=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/2012117162611335.jpg\" rel=\"fancybox_a\"\u003e\u003cimg src=\"http:\/\/www2.chison.com:8880\/Images\/UpFile\/201211716267913.jpg\" alt=\"\"\u003eKindey, CFM Mode\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e","brand":"Used Ultrasounds","offers":[{"title":"Default Title","offer_id":12339721666645,"sku":"Q8KM","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0319\/3397\/products\/q8a.jpg?v=1571438507","url":"https:\/\/www.keebovet.com\/products\/chison-q8","provider":"KeeboVet Veterinary Ultrasound Equipment","version":"1.0","type":"link"}