{"product_id":"ebit10","title":"eBit 10Vet","description":"\u003ch2 style=\"text-align: left;\"\u003e\u003cstrong\u003eeBit 10Vet Latest Model - Best Quality BW Ultrasound\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eAdvantages:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eThe ultrasound that many are looking for.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eeBit 10Vet was designed by KeeboVet based on the customer requirements.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBest image quality among all black white ultrasound across the globe.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSame image quality as eBit50 without color doppler.\u003c\/li\u003e\n\u003cli\u003eHigh frequency probes 5-18MHz.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eColor function is optional and it is additional $5000.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eEquine tendon - best.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eEquine bovine work - perfect.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmall animals - excellent \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eEven small nerves can be seen.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003eSame quality as eBit50 and eBit60, which are more than 15K. In order keep high image quality and have good price we removed color doppler function and some other functions not relevant to veterinarians. \u003c\/p\u003e\n\u003cp\u003eMany exams in animals require high frequency especially with very small animals shallow examinations. eBit 10Vet has a linear array probe with 7-18MHz, and currently it is the only b\/w ultrasound with such a high-frequency under 7K. This would be very useful in tendon examinations, rodents, reptiles and other small animals.\u003c\/p\u003e\n\u003cp\u003eThe rectal probe for Equine and Bovine exams is unique: 5-14MHz frequency, 70mm long lens and amazing 126 elements. \u003c\/p\u003e\n\u003cp\u003eMicro convex probe for small animals has frequency of 5-13MHz.\u003c\/p\u003e\n\u003cp\u003eUnique probe frequency Linear Array 7-18Mhz, perfect for shellow examination.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch3\u003e\u003cspan\u003ePortable Ultrasound Diagnostic System\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003eGeneral information\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"page\" title=\"Page 2\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions and Weight of Main Unit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e Dimensions: 358mm(Length)×125mm(Width)×399mm (Height)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e Net Weight without probe: 7.8kg\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n \u003cstrong\u003eElectrical Power\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cul\u003e\n\u003cli\u003ePower supply voltage: Autoadaptable for AC100-240V\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower supply frequency: 50-60Hz\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower consumption: 150VA\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cstrong\u003eUser interface Operation Panel \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eControl panel\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAlphanumeric keyboard\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e8 STC Slides\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eInteractive back lit keys\u003c\/li\u003e\n\u003cli\u003eHigh-resolution color LCD\u003cbr\u003e\n\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eDiagonal dimension: 15 inch\u003c\/li\u003e\n\u003cli\u003eResolution: 1024X768\u003c\/li\u003e\n\u003cli\u003eBrightness adjustment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eIntegrated speaker\u003cbr\u003e\n\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eVolume adjustable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSystem overview \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eApplications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAbdominal\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmall parts\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePeripheral\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eVascular \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTransvaginal\u003c\/li\u003e\n\u003cli\u003eTrans-rectal\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMusculoskeletal \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePediatric\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eFetal\u003c\/li\u003e\n\u003cli\u003eOB\u003c\/li\u003e\n\u003cli\u003eGYN\u003c\/li\u003e\n\u003cli\u003eUrology \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"page\" title=\"Page 3\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cstrong\u003eTransducer Types \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConvex Probe: C3-E\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLinear: L7-E, L12-E\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTrans-Rectal: L7R-E, L7V-E\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMicro-convex: MC3-E, MC6-E, MC5-E\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cstrong\u003eImage Modes \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eB Mode\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eB\/M Mode\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eM Mode\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e2B Mode\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e4B Mode\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e2DSteer (optional)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePW Mode\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTrapezoidal Mode\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cstrong\u003eDisplay Mode\u003c\/strong\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eQuad\/dual display\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDuplex mode: B\/M\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDisplay Annotation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLogo\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eHospital name\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eExam Date\/Time\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMechanical index\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTissue thermal index\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePatient Name and Patient ID\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eGender\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBirthday, Age\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSonographer\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLMPGAEDD\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSystem status (real-time or frozen)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCineguide\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeasurement summary window\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeasurement results window\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProbe type\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFrequency\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMenuindication\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTrack-ball functions indication\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eImaging parameters\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"page\" title=\"Page 4\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-resolution 15\" LCD Display\u003c\/li\u003e\n\u003cli\u003e2 Active probe ports\u003c\/li\u003e\n\u003cli\u003ePulse Wave Doppler (PW)\u003c\/li\u003e\n\u003cli\u003ePower Doppler Flow Imaging\u003c\/li\u003e\n\u003cli\u003e≥500G integrated hard disk\u003c\/li\u003e\n\u003cli\u003eUSB ports: 4\u003c\/li\u003e\n\u003cli\u003eEthernet port: 1\u003c\/li\u003e\n\u003cli\u003eS-video outport: 1\u003c\/li\u003e\n\u003cli\u003eVGA port: 1\u003c\/li\u003e\n\u003cli\u003eDVI port: 1\u003c\/li\u003e\n\u003cli\u003eFootswitch: 1\u003c\/li\u003e\n\u003cli\u003eRemote:1\u003c\/li\u003e\n\u003cli\u003eGeneral measurement package\u003c\/li\u003e\n\u003cli\u003eClinical measurement packages\u003c\/li\u003e\n\u003cli\u003eMulti-language screen display\u003c\/li\u003e\n\u003cli\u003eReview: images review system\u003c\/li\u003e\n\u003cli\u003eArchive: patient information management system\u003c\/li\u003e\n\u003cli\u003eReporting system\u003c\/li\u003e\n\u003cli\u003eAIO(AutomaticImageOptimization)\u003c\/li\u003e\n\u003cli\u003eIntelligent Zoom\u003c\/li\u003e\n\u003cli\u003eSpeckle Reduction Algorithm (SRA)\u003c\/li\u003e\n\u003cli\u003eQ-Imagesoftwarepackage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"page\" title=\"Page 5\"\u003e\n\u003cp class=\"layoutArea\"\u003e\u003cstrong\u003eSoftware Options\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDICOM (storage, SR, print, worklist)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eECG\u003c\/li\u003e\n\u003cli\u003e2D Steer Hardware Option\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConvex transducer: C3-E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003c\/span\u003eLinear transducer: L7-E, L12-E\u003c\/li\u003e\n\u003cli\u003eTrans Rectal transducer: L7R-E, L7V-E\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMicro-convex transducer: MC3-E, MC6-E, MC5-E \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFootswitch \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCarrying case \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTrolley \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eECGcable \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBag\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"layoutArea\"\u003e\u003cstrong\u003ePeripherals\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eVideo printers: \u003c\/strong\u003e\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eSONY UP897MD, SONY UP-D711MD, SONY UP-X898MD\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e PC printers: \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eEPSON L120 Series\u003c\/li\u003e\n\u003cli\u003eEPSON L130 Series\u003c\/li\u003e\n\u003cli\u003eEPSON L310 Series\u003c\/li\u003e\n\u003cli\u003eEPSON L380 Series\u003c\/li\u003e\n\u003cli\u003eEPSON L805 Series\u003c\/li\u003e\n\u003cli\u003eEPSON L1110 Series\u003c\/li\u003e\n\u003cli\u003eEPSON L1118 Series\u003c\/li\u003e\n\u003cli\u003eHP DeskJet 1010 series\u003c\/li\u003e\n\u003cli\u003eHP OfficeJet Pro 6230\u003c\/li\u003e\n\u003cli\u003eHP LaserJet 1020 Plus\u003c\/li\u003e\n\u003cli\u003eHP LaserJet P2055d\u003c\/li\u003e\n\u003cli\u003eHP LaserJet Pro M12a\u003c\/li\u003e\n\u003cli\u003eHP LaserJet Pro P1102\u003c\/li\u003e\n\u003cli\u003eHP LaserJet Pro P1102w\u003c\/li\u003e\n\u003cli\u003eHP LaserJet Pro P1108\u003c\/li\u003e\n\u003cli\u003eHP LaserJet Pro 200 color M251n\u003c\/li\u003e\n\u003cli\u003eHP Color LaserJet Pro M252n\u003c\/li\u003e\n\u003cli\u003eHP Color LaserJet Pro M252dw\u003c\/li\u003e\n\u003cli\u003eHP Color LaserJet Pro M254nw\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"page\" title=\"Page 6\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cstrong\u003eImaging processing and presentation \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eB Mode\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eGain: 0~255, 256levels\u003c\/li\u003e\n\u003cli\u003eFramerate: MAX:1801(depends on probes)\u003c\/li\u003e\n\u003cli\u003eSTC: 8 segments\u003c\/li\u003e\n\u003cli\u003eDepth:MAX:36.7cm(dependsontheprobes)\u003c\/li\u003e\n\u003cli\u003eFreq.:MIN:2MHz,MAX:H18MHz(dependsontheprobes)\u003c\/li\u003e\n\u003cli\u003eFHI:ON\/OFF\u003c\/li\u003e\n\u003cli\u003eAIO:ON\/OFF\u003c\/li\u003e\n\u003cli\u003eInvert:ON\/OFF\u003c\/li\u003e\n\u003cli\u003eX-CONTRAST:Normal\/Enhance\/Suppress,3levels\u003c\/li\u003e\n\u003cli\u003eU\/Dflip\u003c\/li\u003e\n\u003cli\u003eZoom\u003c\/li\u003e\n\u003cli\u003eFullscreen\u003c\/li\u003e\n\u003cli\u003eFocusnumber:1~8,8levels(dependsontheprobes)\u003c\/li\u003e\n\u003cli\u003eCompound:ON\/OFF\u003c\/li\u003e\n\u003cli\u003eSRA:ON\/OFF\u003c\/li\u003e\n\u003cli\u003eDensity:High\/Low\u003c\/li\u003e\n\u003cli\u003eDynamic:30~165,16levels\u003c\/li\u003e\n\u003cli\u003eFocus position: 1cm~16cm, 16 levels\u003c\/li\u003e\n\u003cli\u003eQ-Image:0~3,4levels\u003c\/li\u003e\n\u003cli\u003ePersistence:0~7,8levels\u003c\/li\u003e\n\u003cli\u003eB Rejection:0~256,257levels\u003c\/li\u003e\n\u003cli\u003eScan width:14%~100%,16levels\u003c\/li\u003e\n\u003cli\u003eGamma:0~8,9levels\u003c\/li\u003e\n\u003cli\u003eSmooth:0~7,8levels\u003c\/li\u003e\n\u003cli\u003eEdge enhance:0~6,7levels\u003c\/li\u003e\n\u003cli\u003eAcoustic power:0~100%,101levels\u003c\/li\u003e\n\u003cli\u003eL\/R Flip:ON\/OFF\u003c\/li\u003e\n\u003cli\u003eRotation:0~270,4levels\u003c\/li\u003e\n\u003cli\u003eChroma:0~28,29levels\u003c\/li\u003e\n\u003cli\u003e2D Map:default,1~20,21levels\u003c\/li\u003e\n\u003cli\u003eScreen brightness:20~100,17levels\u003c\/li\u003e\n\u003cli\u003eZoom coef:60%~100%,8levels\u003c\/li\u003e\n\u003cli\u003eTrapezoidal imaging (only for linear transducer):ON\/OFF\u003c\/li\u003e\n\u003cli\u003e2D steer (only for linear transducer):-20~20,41levels\u003c\/li\u003e\n\u003cli\u003eECG:ON\/OFF\u003c\/li\u003e\n\u003cli\u003eBiospy:ON\/OFF\u003c\/li\u003e\n\u003cli\u003eNeedle Angle (only for linear transducer):-30~30\u003c\/li\u003e\n\u003cli\u003eCenter Line:ON\/OFF\u003c\/li\u003e\n\u003cli\u003eLGC: ON\/OFF\u003c\/li\u003e\n\u003cli\u003eKeyboard light:ON\/OFF\u003c\/li\u003e\n\u003cli\u003eLight intensity:1~16,16levels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eM Mode\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eDynamic:30~165,16levels\u003c\/li\u003e\n\u003cli\u003eM Chroma:0~8,9levels\u003c\/li\u003e\n\u003cli\u003eSpeed:1~4,4levels\u003c\/li\u003e\n\u003cli\u003eLayout:LR\/UD,2levels\u003c\/li\u003e\n\u003cli\u003eM2D map:default,1~20,21levels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePW Mode\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eGain:0~255,256levels\u003c\/li\u003e\n\u003cli\u003eFreq.:MIN:2MHz,MAX:15MHz (depends on the probes)\u003c\/li\u003e\n\u003cli\u003eWall Filter: 0~3, 4 levels\u003c\/li\u003e\n\u003cli\u003eTriplex mode\u003c\/li\u003e\n\u003cli\u003eSteer:-20~20,5levels\u003c\/li\u003e\n\u003cli\u003eInvert:ON\/OFF\u003c\/li\u003e\n\u003cli\u003ePW chroma: 0~28, 29 levels\u003c\/li\u003e\n\u003cli\u003eAudio:0~100%,101levels\u003c\/li\u003e\n\u003cli\u003ePRF: MIN: 250Hz, MAX: 20kHz\u003c\/li\u003e\n\u003cli\u003eSpeed:0~2,3levels\u003c\/li\u003e\n\u003cli\u003eBaseline:0~6,7levels\u003c\/li\u003e\n\u003cli\u003eAngle:0~70,8levels\u003c\/li\u003e\n\u003cli\u003eSV:0.5~20mm,8levels\u003c\/li\u003e\n\u003cli\u003eD2Dmap:default,1~20,21levels\u003c\/li\u003e\n\u003cli\u003eSpectrumEnhance:0~3,4levels\u003c\/li\u003e\n\u003cli\u003eDynamicRange:46~67,8levels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"page\" title=\"Page 8\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCineloop\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eSupport 2D,M,PW\u003c\/li\u003e\n\u003cli\u003eCine-loop auto\/manual\u003c\/li\u003e\n\u003cli\u003eVariable cine play back speed\u003c\/li\u003e\n\u003cli\u003eUser-define start and end frame of cine storage\u003c\/li\u003e\n\u003cli\u003eUser-define start and end frame of cine review\u003c\/li\u003e\n\u003cli\u003estorage in hard disk and display in real-time modes\u003c\/li\u003e\n\u003cli\u003eSlideshow: slideshow function\u003c\/li\u003e\n\u003cli\u003eStorage ≥500GB integrated hard-drive\u003c\/li\u003e\n\u003cli\u003eUSBdriver\u003c\/li\u003e\n\u003cli\u003eStill images storage format: BMP\u003c\/li\u003e\n\u003cli\u003eStill images export format: BMP,JPG,DCM  \u003c\/li\u003e\n\u003cli\u003eCineloops storage format: CINE\u003c\/li\u003e\n\u003cli\u003eCineloops export format: AVI\u003c\/li\u003e\n\u003cli\u003eReview Image review Layout: 1×1,2×2,4×4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp class=\"layoutArea\"\u003e\u003cstrong\u003eImage management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cul\u003e\n\u003cli\u003eArchive\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePatient Info\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eReview Report\u003cbr\u003e\n\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eBackup exam\u003c\/li\u003e\n\u003cli\u003eRestore exam\u003c\/li\u003e\n\u003cli\u003eSend exam\u003c\/li\u003e\n\u003cli\u003eDelete exam\u003c\/li\u003e\n\u003cli\u003ePatient view\u003c\/li\u003e\n\u003cli\u003eStudy view\u003c\/li\u003e\n\u003cli\u003eExpand all\u003c\/li\u003e\n\u003cli\u003eCollapse all\u003c\/li\u003e\n\u003cli\u003eSelect all\u003c\/li\u003e\n\u003cli\u003eNew Exam\u003c\/li\u003e\n\u003cli\u003eContinue Exam\u003c\/li\u003e\n\u003cli\u003eEdit Exam\u003c\/li\u003e\n\u003cli\u003eReview\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"page\" title=\"Page 9\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"page\" title=\"Page 10\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement \u0026amp; calculation \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGeneral Measurement Package\u003cbr\u003e\n\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eSoftware packages for various specific clinical use\u003c\/li\u003e\n\u003cli\u003eComprehensive analysis methods\u003c\/li\u003e\n\u003cli\u003eClinical analysis reports\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral measurement package \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGeneral B mode measurement\u003cbr\u003e\n\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eDistance\u003c\/li\u003e\n\u003cli\u003eCircumference\/area\u003c\/li\u003e\n\u003cli\u003eVolume(3Distances)\u003c\/li\u003e\n\u003cli\u003eVolume(2Distances)\u003c\/li\u003e\n\u003cli\u003eVolume(1 Distance)\u003c\/li\u003e\n\u003cli\u003eVolume(1 Ellipse)\u003c\/li\u003e\n\u003cli\u003eVolume(1Ellipse1Dis)\u003c\/li\u003e\n\u003cli\u003eRatio(distance\/ area)\u003c\/li\u003e\n\u003cli\u003eAngle\u003c\/li\u003e\n\u003cli\u003eStrain Ratio\u003c\/li\u003e\n\u003cli\u003eHistogram\u003c\/li\u003e\n\u003cli\u003eprofile\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eM mode measurement\u003cbr\u003e\n\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eDistance\u003c\/li\u003e\n\u003cli\u003eTime\u003c\/li\u003e\n\u003cli\u003eVelocity\u003c\/li\u003e\n\u003cli\u003eHeart Rate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eGeneral PW mode measurement\u003cbr\u003e\n\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eVelocity\u003c\/li\u003e\n\u003cli\u003eDistance\u003c\/li\u003e\n\u003cli\u003ePeak\u003c\/li\u003e\n\u003cli\u003eTrace\u003c\/li\u003e\n\u003cli\u003eStD%\u003c\/li\u003e\n\u003cli\u003eStA%\u003c\/li\u003e\n\u003cli\u003eICA\/CCA\u003c\/li\u003e\n\u003cli\u003eVolume Flow\u003c\/li\u003e\n\u003cli\u003eHeart Rate \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"page\" title=\"Page 11\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cstrong\u003eClinical Analysis Packages \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCanine\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFeline\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eEquine\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBovine\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eOvine\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCardiology \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"page\" title=\"Page 12\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cstrong\u003eProbe Parameter \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConvex transducer: \u003cbr\u003e\n\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eC3-E, 3.5MHz, 2.0-6.8MHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eLinear transducer:\u003cbr\u003e\n\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eL7-E, 7.5MHz, 4.0-15.0MHz \u003c\/li\u003e\n\u003cli\u003eL12-E, 12.0MHz, 7.0-15.0MHz\u003c\/li\u003e\n\u003cli\u003eL7R-V, 7.5MHz, 4.0-15.0MHz\u003c\/li\u003e\n\u003cli\u003eL7W-E, 7.5MHz, 4.0-15.0MHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eMicro-convex transducer:\u003cbr\u003e\n\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eMC3-E, 3.0MHz, 2.0-6.8MHz\u003c\/li\u003e\n\u003cli\u003eMC5-E, 5.0MHz, 4.0-10.7MHz\u003c\/li\u003e\n\u003cli\u003eMC6-E, 6.0MHz, 4.0-12.0MHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSystem setup \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBy using system Setup, users could \u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCustomize hospital information\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCustomize Patient\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCustomize Date and time\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCustomize language\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCustomize Screen Controller\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCustomize Trackball Option\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCustomize Auto Export\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCustomize screen type\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCustomize Cine Frames\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCustomize Print De-Identification\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eOption for Image Area\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eOption for Transmitted Images\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePC Print Image Option\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCustomize hotkey functions\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFunction Config\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCustomize Unit\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCustomize Measure Option\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCustomize Measure Result\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCustomize Follicle\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCustomize Heart Rate\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCustomize AutoTrace\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eOB Table\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCustomize measurement package\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCustomize comment\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCustomize bodymark\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCustomize exam mode\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCustomize Image Freeze Config\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCustomize Report\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDICOM setting\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNet setting\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCustomize Storage\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCustomize Net Printwe\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSystem information\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003efunction setting\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ehardware function\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eInstallment\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eVideo\u0026amp;VGA setting\u003c\/li\u003e\n\u003cli\u003eSystem Maintainance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"page\" title=\"Page 13\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\u003cstrong\u003eUser Define Functions\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003eBy user-define function, users could \u003c\/span\u003e\u003cspan\u003ecustomize user-define preset, including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eApplications name,\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePresets name,\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eUser defined name\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eApplications exam type\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eImaging parameters\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eMulti-language Display Interface \u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnglish\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eChinese\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eOther languages\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNote: other languages for detailed, please contact us.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003eInputs \u0026amp; outputs \u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSystem power in: 1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eEthernet: 1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eS-video: 1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFootswitch port: 1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eUSB port: 4\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eVideo out: 1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemote control: 1  VGA: 1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDVI: 1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eECG port: 1\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\nOperating conditions\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"page\" title=\"Page 14\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient temperature: 10°C to 40°C\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 30% to 75%\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eatmospheric pressure: 700 hPa to 1060 hPa\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\nStorage and transport conditions\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient temperature: -5°C to 40°C\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eRelative humidity: ≤80%\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAtmospheric pressure: 700 hPa to 1060 hPa\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"KeeboVet Veterinary Ultrasound Equipment","offers":[{"title":"Default Title","offer_id":19591156596858,"sku":"EBIT10KM","price":11999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0319\/3397\/products\/IMG-0848.jpg?v=1581592846","url":"https:\/\/www.keebovet.com\/products\/ebit10","provider":"KeeboVet Veterinary Ultrasound Equipment","version":"1.0","type":"link"}