Vet Monitor Biolight BLT M8000

$ 1899.00 Sale

Biolight BLT M8000 Patient Monitor

Used in hospital and clinics for measuring patients ECG, Respiratory, NIBP, SPO2, Temperature, IBP, EtCO2 parameters, FDA approved in the USA. Specific veterinary software for bovine, equine, canine, feline, and ovine.

Product Features

  • 10.4’’ LCD display, high resolution
  • 7 lead ECG Waveform display
  • Large number display for long distance vision
  • Digital SPO2 technology offers anti-motion and anti-low perfusion functions
  • Up to 66 beds network capacity to connect with HIS
  • 120 hours tabular and graphic trends & data storage
  • Drug dose calculation
  • OXYCRG software

Technical Specifications

  • Safety: IEC60601 (GB9706)
  • Dimensions: 318mm (W) x 264mm (H) x 152mm(D)
  • Power Supply: 100~240V; AC: 50~ 60 Hz
  • Alarm Indication: Visual and audible alarm 1000 groups of alarm events review
  • Application: Adult, pediatric and neonate

ECG

  • Leads: I, II, III, aVR, aVL, aVF, V
  • Gains: 2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mV, 40mm/mV, auto
  • Input impedance: =5MO (d.c.~60Hz)
  • Common Mode Rejection Ratio: =85dB (diagnostic mode) =105dB (monitoring & surgical mode)
  • Bandwidth: 0.5-40Hz (monitoring mode) 0.05-120Hz (diagnostic mode) 1-25Hz (surgical mode)
  • Protection: Segregation breakdown voltage 4000VAC, 50/60Hz Resistant to high-frequency electrotome, myoelectricity, AC, drifting interference
  • Indication of Detachment of electrodes: Available
  • Playback of Cardiogram: Available
  • Scanning Speed: 12.5mm/s, 25mm/s, 50mm/s
  • Heart Rate Range:10-300BPM
  • Accuracy: ±1BPM ECG
  • Waveform Playback: 10 minutes

NIBP

  • Method: Automatic oscillometric
  • Operation Modes: Singles (manual), Cycle (automatic), Rapid (continuous)
  • Measurement: Systolic pressure/diastolic pressure/mean pressure
  • Range:
    • Adult: 10-270mmHg
    • Pediatric: 10-235mmHg
    • Neonate: 10-135mmHg
  • Unit: mmHg / Kpa selectable
  • Auto Measurement: 1, 2, 3, 4, 5, 10, 15, 20, 30, 45, 60, 90 minutes, 2, 4, 8, 12 hours
  • 750 groups of NIBP measuring data review

RESP

  • Method: Impedance Measurement
  • Measuring Range: 0-120bpm
  • Alarm Limit: 0-120bpm, upper and lower limit continuously adjustable
  • Apnea alarm: Available

BLT

  • Digital SPO2 (Pulse Oximetry)
  • Range: 0-100%
  • Accuracy: ±2% (70%~100%); ±3%(35%~ 69%)
  • Unspecified: (0~34%)
  • Range & Accuracy of Pulse Rate: 20~250BPM ± 1BPM

TEMP

  • Channel: 2 channels
  • Range: 0~50º
  • Unit: Celsius, Fahrenheit
  • Resolution: 0.1º
  • Accuracy: ±0.1? (25º~50º)
  • Alarm Range: 0~50º

Optional

  • IBP
    • Channel: 2 channels
    • Range: -50~300 mmHg
    • Resolution: 1 mmHg
    • Accuracy: ±2 mmHg (±2%) without probe ±4 mmHg (±2%) with probe
    • Unit: mmHg, Kpa
    • Converter Sensitivity: 5 uV/V/mmHg
    • Names of Pressures: ART/PA/CVP/LAP/RAP/ICP
  • EtCO2 (side stream)
    • Method: Infrared spectrum
    • Range: 0.0-13.1%
    • Resolution: 1 mmHg (0.1%)
    • Accuracy: 5% EtCO2